DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1153STBY-SPE (Standby SPE)
10
NOTE:
When more than one of the above error types exists at the same time, the
alarm against the Standby SPE is cleared only when (1) any problems
described by the Aux Data values for Error Types 1 and 257 are resolved
and (2) all problems described in (b) through (o) are resolved.
Notes:
a. Aux Data value 0 is equivalent to Aux Data value 2017. All Aux Data values
listed for Error Type 1 are described in "System Technician-Demanded
Tests: Test Result Error Codes". These values are shared between
Standby SPE maintenance activity results and the test results for the
System Technician commands on Standby SPE components because the
values represent the common set of problems that can be encountered
when attempting to conduct any form of maintenance activity on the
Standby SPE.
b. Error Type 58 is logged when the Duplication Interface circuit pack in the
A carrier reports that the Standby SPE has gone into Down Mode. This
implies an inability to communicate with the Standby SPE.
The ability to communicate with the Standby SPE should be checked by
issuing the test processor a | b short command, where "a | b" indicates
the carrier that contains the Standby SPE. If all of the tests execute such
that no test returns an Aux Data value of 2014, 2015, 2016, 2017, 2022,
2024, or 2025, the Standby SPE was successfully put into Maintenance
Mode. This indicates that the communication path between the Active SPE
and the Standby SPE may be functional. However, to restore the
1. Run the short test sequence first. If all the tests pass, run the long test sequence. Refer to the
appropriate test description and follow the recommended procedures.
812 (y) any SPE interchanged
forced with
health-override
option:
WARNING OFF See note (y).
822(z) any A non-hot
interchange to the
standby SPE
occurred.
See note (z).
826 (aa) any Standby software
mismatch
MAJOR ON upgrade software
Table 10-409. Standby SPE Error Log Entries — Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page