Maintenance Commands and Trouble-Clearing Aids
Page 8-49display cabinet
8
display cabinet
This command displays the cabinet description and location and the carrier
description for a selected cabinet number.
Alt Name Identifies the location of maintenance object, as follows:
Station = extension number
Trunk = Group number (78/__) or group and member
numbers (78/01)
Private CO Line = private CO line (P) and group number.
(P/xxx)
Alarm Type Alarm level: MAJOR, MINOR, or WARNING
Service State Identifies the service state of the station and trunk ports, as
follows:
RDY = ready for service
OUT = out of service
IN = in service
[Blank] = No associated service state
Ack? Headings 1 and 2 identify the first and second OSS telephone
numbers, respectively. The entries below indicate the
acknowledged alarm state:
Y (yes) = alarm has been acknowledged
N (no) = alarm has not been acknowledged
C (cleared) = alarm was first acknowledged, then resolved
and cleared
[Blank] = no attempt was made to report the alarm
NOTE:
If the user disables the alarm origination with the change
system-parameters maintenance command, then the
Ack? field is blank regardless of the true acknowledged
state of the alarm.
Date Alarmed Indicates the month, day, hour, and minute of the alarm.
Date Resolved Indicates the month, day, hour, and minute of the resolution. For
active alarms, this field contains zeros (0).