DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-417DID-TRK (DID Trunk)
10
Port Diagnostic Test (#35)
This test checks a port’s battery feed circuitry. The battery feed circuitry is tested
for on-/off-hook detection, battery shutdown, and battery reversal (WINK)
capabilities.
0NO
BOARD
The test could not relate the internal ID to the port (no board).
1. Check to ensure that the board translations are correct. Translate the
board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish the linkage
between the internal ID and the port.
Table 10-135. TEST #35 Port Diagnostic Test
Error
Code
Test
Result Description/ Recommendation
ABORT System resources required to run this test were not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
Continued on next page
Table 10-134. TEST #33 Loop Around and Conference Circuit Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page