DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1249TAPE (Tape Unit) [G3iV1.1-286]
10
9024 No tape cartridge in tape
drive.
1. Do the steps below following the directions
in the ‘‘
Tape Maintenance and Repair
Procedures’’ section.
2. Issue the test tape long command.
3. If the test fails, make sure tape is fully
inserted.
4. If the test continues to fail, clean the tape
head and retest.
5. If fail, swap tape and retest.
6. If the test still fails, swap tape unit,
use
original tape
and retest.
7. If the problem still exists, escalate the
problem.
9025 Tape cartridge is worn, and it
is NOT functional.
1. Do the steps below following the directions
in the ‘‘
Tape Maintenance and Repair
Procedures’’ section.
2. Clean the tape head.
3. If still fail, check tape insertion, swap tape if
necessary, and retest.
4. Replace tape unit as a last resort.
5. If the problem still exists, escalate the
problem.
Table 10-433. Table A: Tape Unit Aux Data Table — Continued
Aux Data/
Error Codes Explanation Strategy
Continued on next page