DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-919PDMODULE, TDMODULE (Data Module)
10
2000 ABORT Response to the test request was not received within the allowable time
period.
1. Retry the command at one-minute intervals a maximum of five
times.
2. If the test continues to abort, escalate the problem.
2001 ABORT System resources required to run this test are not available.
1. Retry the test at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Rerun the test at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
2500 ABORT Internal System Error
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, escalate the problem.
15 FAIL The control channel between the processor and Digital Line circuit
pack is not transmitting properly. This can cause a wide range of
effects. The user may notice nothing or the port may be totally
unusable. This could also disrupt other users.
1. Run circuit pack tests to check the Tone Generator and the Tone
Detector circuit packs using the test board UUCSS short
command.
2. Resolve any problems that are detected on the Tone Generator
circuit pack or Tone Detector circuit pack.
3. If the Tone Generator and Tone Detector circuit packs are
functioning properly, and the test still fails, replace the Digital Line
circuit pack.
Table 10-308. TEST #13 Information and Control Channel Local Loop Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page