DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-649EXT-DEV ADMIN? N (External Device Alarm)
10
EXT-DEV ADMIN? N (External Device
Alarm)
NOTE:
Use this Maintenance Object when the
External Device Alarm Admin?
field
on the
change system-parameters customer-options
form is set to (n).
In the Standard Reliability PPN the Maintenance Processor (TN786B or TN790) in
carrier (A) monitors the EXT-DEV alarm leads. In the High or Critical PPN, the
Duplication Interface (TN772) circuit pack in carrier (A) monitors the EXT-DEV
alarm leads, and provides status to the Maintenance processor (TN786B or
TN790) in the active SPE. In the EPN the Maintenance Board (TN775) monitors
the EXT-DEV alarm leads. The system only recognizes pairs connected to the 1M
and 1m (ALARM MONITOR) leads. Pairs connected to the 2M, 2m, 3M, 3m, and
3w are not recognized by the system. Refer to the
DEFINITY Communications
System Generic 1 and Generic 3i Wiring,
555-204-111, for more details.
Hardware Error Log Entries and Test to Clear
Values
1. where UU is an appropriate cabinet number determined via the PORT field from the
Alarm or Error Log.
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2. One port generates a MAJOR alarm; the other port generates a MINOR alarm.
MO Name (in
Alarm Log)
Alarm
Level Initial Command to Run
1
Full Name of MO
EXT-DEV MAJOR test environment UU External Device Alarm
EXT-DEV MINOR test environment UU External Device Alarm
Table 10-218. Hardware Error Log Entries and Test to Clear Values
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test environment UU r2 or
6
1 or 5 Any External Device
Alarm Test (#120)
MAJOR
MINOR
2
OFF test environment UU r 2 or
6