DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1223SYNC (Synchronization)
10
Test Synchronization Test (#417)
This test updates all the Synchronization Maintenance component circuit packs
with the correct information regarding their role in providing synchronization for
the system. All the Tone-Clock, Expansion Interface, and DS1 Interface circuit
packs in the system are updated via this test. This test will either pass or abort.
Table 10-421. TEST #417 Test Synchronization Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS The Synchronization Maintenance component circuit pack parameters have
been successfully updated. The system should be synchronized after
successful execution of this test. If synchronization problems still exist, refer
to the Error Log to obtain information regarding the source of the problem.
Continued on next page