Maintenance Object Repair Procedures
Page 10-441DIG-LINE (Digital Line)
10
Voice and Control Channel Local Loop Test (#13)
These tests check the information and control channels between the Switch
Processing Element (SPE) and the Digital Line port circuit. The SPE sends a
message to loop around both the information and control channels for the port.
Table 10-144. TEST #11 Digital Line Electronic Power Feed Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal System Error
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not available. The port may
be busy with a valid call. Use display port PCSSpp to determine the
station extension or attendant number of the port. Use status station or
status attendant to determine the service state of the port. If the service
state indicates that the port is in use, then the port is unavailable for certain
tests. (See Chapter 10, "Maintenance Commands and Trouble-Clearing
Aids", for a full description of all possible states.) You must wait until the
port is idle before retesting. Attendants are always in use (off-hook) if the
handset is plugged in and the port is not busied out.
1. If the port status is idle, then retry the command at 1-minute intervals a
maximum of 5 times.
2. If the test continues to abort, escalate the problem.
FAIL Internal System Error
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
PASS Electronic Power Feed Test passed. The message to turn on the power to
the station was successfully sent to the port.
1. Although this test will never actually return a FAIL result except for the
Internal System Error (naught/FAIL ) described above, it will log an
error indicating the real results of the test. Check the Error Log for any
entries with Error Types 767 or 769 after the test completes.
2. If Error Type 767 appears in the Error Log, this should indicate that the
test sensed no problems with the power to the station. To verify that the
station is powered up correctly, run a self-test on the station, if
available, and check that all the feature buttons are operating.
3. If Error Type 769 appears in the Error Log, this indicates some problem
with the power to the station. Check for a short in the wiring, a
damaged jack, a defective voice terminal, or an incorrect type of
terminal.
Continued on next page