DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1174STBY-SPE (Standby SPE)
10
2016
2017
ABORT The Active SPE attempted to put the Standby SPE into Maintenance Mode, but
did not receive notification from the Standby SPE Maintenance software that it
successfully entered Maintenance Mode OR, once in Maintenance Mode, the
Standby SPE sent a request to the Active SPE to have the Active SPE conduct
a portion of a test in the Standby SPE’s behalf, but the Standby SPE did not
receive a response to its request. In either case, the communication path
between the Active SPE and the Standby SPE may have failed. Follow the
procedures described for Error Code 2024 in the STBY-SPE section.
2018 ABORT The test requires that a maintenance activity request be made to the Standby
SPE; however, the request cannot be made because the Standby SPE is busy
processing a previous maintenance activity request.
1. Issue the refresh spe-standby command to force the Standby SPE to
Standby Mode. This command may have to be issued multiple times. If the
refresh spe-standby command successfully completes five times without
the Standby SPE becoming labeled "standby" on the status system form,
wait 30 minutes. This does not include cases where the command
completes with the terminal message line errors "Refresh not successful;
use ‘display errors’ to check for STBY-SPE errors" or "Cannot interrupt
Standby SPE while entering maintenance mode; please try later." Issue the
refresh spe-standby command once more.
2. Repeat the test.
3. Issue the test spe-standby long command to thoroughly test all Standby
SPE components.
2019 ABORT A translation save on the Standby SPE was not carried out because the
Shadow Link Test failed. (The Shadow Link Test was done to verify the integrity
of the translation data on the Standby SPE.)
1. Check for Memory Shadowing Link errors and alarms. Refer to SHDW-LNK
(Memory Shadowing Link) Maintenance documentation and follow the
prescribed procedures.
Table 10-410. Test Result Error Codes Associated with the Standby SPEContinued
Error
Code
Test
Result Description/ Recommendation
Continued on next page