Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1549WAE-PORT (Wideband Access Endpoint Port)
10
Table 10-523. TEST #7 Conference Circuit Test
Error
Code
Test
Result Description/ Recommendation
ABORT System resources required for this test are not available.
1. Retry the command at one minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not available. The port may
be in use on a valid call. Use the status access-endpoint <extension>
command to determine when the port is available for testing.
1004 ABORT The port has been seized by a user for a valid call. Use the status
access-endpoint <extension> command to determine when the port is
available for testing. The port is available when it is in the in-service/idle
state.
1. Retry the command at one minute intervals a maximum of five times.
2. If the test continues to abort, and if the port is not in use, escalate the
problem.
1020 ABORT The test did not run due either to a previously existing error on the specific
port or to a more general circuit pack error.
1. Examine the Error Log for existing errors against this port or circuit
pack, and attempt to diagnose the previously existing error.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT System resources required for this test are not available.
1. Retry the command at one minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
FAIL The NPE of the tested port did not conference the tones correctly. This
causes noisy and unreliable connections. Although wideband calls do not
use the conferencing feature on the NPE, this failure indicates problems
with the circuit pack hardware.
1. Replace the circuit pack.
PASS The port can correctly conference multiple connections.
1. User-reported troubles on this port should be investigated by using
other port tests and by examining the terminal adapter or the external
wiring.
Continued on next page