DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-329CONFIG (System Configuration)
10
If more than one CONFIG error is logged with an Aux Data of 1 at the
same time, investigate any EXP-INTF (Expansion Interface) errors before
proceeding.
Once the Port circuit pack location has been determined from Table
10-100, use the list configuration all command to determine if the circuit
pack is inserted. If not, insert the pack. If the circuit pack has already been
inserted but the error persists, replace the circuit pack.
Table 10-107. System Configuration Error Log Entries
Error Type Aux Data Port Circuit Pack Location
1 0 GAMUT Circuit Pack
1
1 1 GAMUT Circuit Pack
1
2 0 1E01
2 1 2E01
2 2 3E01
3 0 1E02
3 1 2E02
3 2 3E02
4 0 1E03
4 1 2E03
4 2 3E03
5 0 1E04
5 1 2E04
5 2 3E04
6 0 1E05
6 1 2E05
6 2 3E05
7 0 1E06
7 1 2E06
7 2 3E06
8 0 1E07
8 1 2E07
8 2 3E07
9 0 1E08
9 1 2E08
Continued on next page