Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-175release journal-printer
8
release journal-printer
This command activates maintenance objects associated with a specified
pms-log or wakeup-log link. Hardware tests are executed to verify that the
equipment is functioning.
For general information on journal printer links, see the description of the
‘‘
busyout pms-link’’ command.
For information on journal printers, see the description of the ‘‘
status journal-link’’
command.
Feature Interactions
Specific component maintenance performed on a link sometimes conflicts with
link maintenance, itself. (busied out objects create link setup failure) Frequent
link re-setup attempts may delay faulty component recovery. For best results,
technicians should use busyout to disable attempted link re-setup.
Output
The following output example is a display of the release journal-printer
wakeup-log command.
Alt. Name
Alternate way to identify maintenance objects.
If the Object is The field contains
station extension
trunk
xxx/yyy
(where
xxx
= trunk group number
and
yyy
= member number)
private CO line
P/xxx
(where
xxx
= private CO line group number)
Result
Success status of a busied out object (PASS, ABORT, FAIL)
Error Code
System-generated description of a command failure.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
release
journal-printer
pms-log
wakeup-log
releases links to pms printers. (1)
Releases links to wakeup logging
facilities. (0)
Examples:
release journal-printer pms-log
release journal-printer
wakeup-log
init
inads
craft
nms
none see below