Maintenance Object Repair Procedures
Page 10-32ADX16D-P (16-Port AUDIX Digital Port)
10
Station (Digital) Audits Test (#17)
Digital Terminal Remote Loop Around Test (1201)
NPE Crosstalk Test (#9)
This test verifies that this port’s NPE channel talks on the selected time slot and
that it never crosses over to time slots reserved for other connections. If the NPE
is not working correctly, one-way and noisy connections may be observed. This
test is part of a port’s Long Test Sequence, and it takes about 20 to 30 seconds
to complete.
Crosstalk testing is performed on both the primary information channel (voice)
and on the secondary information channel (data) associated with each DEFINITY
AUDIX port. If this test fails on either channel, the voice port is taken
out-of-service.
Table 10-13. TEST #9 NPE Crosstalk Test
Error
Code
Test
Result Description/Recommendation
1 ABORT During testing of the primary information channel, system resources may
not have been available. Also, the port may have been busy during the
test.
1. Check the port status. Use the display port PCSSpp command to
determine the voice port extension of the port. Use the status station
command to determine the service state of the port. If the port is in
use, it is unavailable for this test. Wait until the port is idle (a).
2 ABORT System resources may not have been available, or the port may have been
busy during the test.
1. Check if port is being used try (a)
1000 ABORT System resources required to run this test are not available. The port may
be in use. Use the display port PCSSpp command to determine the voice
port extension of the port. Use the status station command to determine
the service state of the port. If the port is in use, it is unavailable for certain
tests. Refer to “Status” commands in Chapter 8, "Maintenance Commands
and Trouble-Clearing Aids", for a full description of all possible states. Wait
until the port is idle before testing.
1. If the port status is idle, try (a)
1001 ABORT System resources required to run this test are not available. Try (a)
1002 ABORT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions, or it may have time slots out-of-service due
to TDM-BUS errors. Refer to “TDM-BUS” to diagnose TDM-BUS errors.
1. If system has no TDM-BUS errors, and if it is not handling heavy traffic,
try (a)