DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-708ISDN-LNK (ISDN-PRI Signaling Link Port)
10
Table 10-237. TEST #643 Signaling Link Board Check
Error
Code
Test
Result Description/ Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1700 ABORT Rollabout video abort. The PRI terminal adapter associated with this
D-channel port is detached from the circuit pack. This is a normal abort
when the rollabout video feature is enabled. To complete test on this port,
either:
1. Re-attach the disconnected PRI terminal adapter and retry test
command, or
2. Disable the rollabout video feature on this circuit pack by entering
change ds1 PCSS and set the field "Alarm when PRI Endpoint
Detached?" to "y."
8 FAIL The DS1 circuit pack is not in-service.
1. Check the Hardware Error Log for entries logged against DS1-BD and
consult the DS1-BD (DS1 Interface Circuit Pack) Maintenance
documentation for repair procedures.
PASS The DS1 Interface circuit pack transporting the ISDN-PRI Signaling Link
Port is in-service.