DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-197BRI-SET, ASAI-ADJ, BRI-DAT
10
1144 ABORT The PPN Packet Bus is out-of-service.
1. Follow the repair procedures for the Packet Bus in the PPN.
2. After completing Step 1, execute the test port long PCSSpp
command, and review the results of the BRI Port Local LAN Loop
Around Test to verify the repair.
1187 ABORT The circuit pack, port or station may have been busied out by a technician.
1. Look in the Error Log for Error Type 18 (busied out ) for BRI-BD,
BRI-PORT, or BRI-SET.
2. If this error type is present for BRI-SET only, then release the station via
the release station command.
a. If this error type is present for BRI-PORT and BRI-SET, then release
the port via release port PCSSpp command and run the test
again.
b. If the error is present for BRI-BD, BRI-PORT, and BRI-SET, then
release the circuit pack via the release port PCSSpp command
and run the test again. If the error is present for both BRI-BD and
BRI-PORT, then release the circuit pack via the release board
PPCSS command and run the test again. If the error is present for
BRI-SET only, then release the circuit pack via the release port
PPCSS command and run the test again.
NOTE:
When you release the circuit pack, you release all ports
associated with it. If certain ports still need to be busied
out, use the release port PCSSpp command to busy
them out.
3. Make sure the terminal is connected.
4. Retry the command at one-minute intervals a maximum of five times.
5. If the test continues to abort, escalate the problem.
2012 ABORT Internal System Error.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
2068 ABORT The endpoint has rejected the switch sent application message. This
indicates that the endpoint does not support the ISDN-BRI Management
and Maintenance Procedure for Loop Back Testing.
1. Use the change station extension command and change the MIMs
Supported field to "no."
Table 10-70. TEST #627 BRI Remote Loop Back — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page