DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-401test tsc-administered
8
Field descriptions
test tsc-administered
This command submits a switched services request to run the Temporary
Signaling Connection’s heartbeat test for all administered TSCs on a signaling
group.
Port The port address: cabinet-carrier-slot-circuit
Maintenance
Name
The name of maintenance object being tested.
Alt. Name The alternate means of identifying the maintenance object. If the
object is a trunk, the field contains xxx/yyy (where
xxx
= trunk
group number,
yyy
= member number). If the object is a private
CO line, the field contains P/xxx (where
xxx
= private CO line
group number).
Test No The test number being executed
Result The result of the individual test: PASS, ABORT, FAIL, NO BOARD,
DISABLED, and EXTRA BD.
Error Code A system-generated number indicating the reason that the test for
the named MO failed or aborted.
test trunk 78
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C1505 CO-TRK 078/001 3 PASS
01C1505 CO-TRK 078/001 36 PASS
Command Successfully Completed