DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-336test ds1-loop
8
Output
The following example shows the output from the test data-module 300
command. The responses display on a test-by-test basis with one line of data for
each test result.
Field Definitions
test ds1-loop
This command validates that the board exists at the specified location and that
the board is a TN464F or TN767E or later suffix DS1 Interface board.
Long-duration loopback tests execute for an extended period of time until
manually terminated. Short-duration loopback tests return the result of the test to
the screen after executing. The list measurements ds1 summary command
can be used to monitor the status of a long-duration loopback/span test.
Port Port address (cabinet-carrier-slot-circuit)
Maintenance
Name
The name of maintenance object
Alt. Name Alternate way to identify maintenance objects.
If the Object is The field contains
station extension
trunk
xxx/yyy
(where
xxx
= trunk group number
and
yyy
= member number)
private CO line
P/xxx
(where
xxx
= private CO line group
number)
Test No The test being executed
Result Test result: Pass, Fail, Abort, No Board
Error Code Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
test data-module 300
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C1103 PDMODULE 17 PASS
Command successfully completed