DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-887M/T-DIG (Maintenance/Test Digital Port) [G3iV1-1.286, G3iV2-386]
10
Hook State Inquiry (#566)
This test ensures that the Maintenance/Test Digital Port maintenance software
and call processing agree on the on-/off-hook status of the Maintenance/Test
Digital Port.
1138 ABORT This test does not run on Port 3 of the Maintenance/Test circuit pack.
This test runs only on Port 2. Look at the results of the Digital Port Sanity
Test for Port 2.
1. Run the command again for Port 2 via the test port PCSS02 or test
port PCSS02 l command.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT System resources required to run this test are not available.
2500 ABORT An internal operation failed; the test could not be completed.
1. Retry the command at one-minute intervals a maximum of five
times.
2. If the test continues to fail, escalate the problem.
50 FAIL The switch was unable to communicate with the port circuitry used for
digital trunk testing.
100 FAIL Data was not sent from Port 2 to Port 3 successfully in asynchronous
mode.
101 FAIL Data was not sent from Port 3 to Port 2 successfully in asynchronous
mode.
102 FAIL Data was not sent from Port 2 to Port 3 successfully in synchronous
mode.
103 FAIL Data was not sent from Port 3 to Port 2 successfully in synchronous
mode.
1. Reset the circuit pack via the busyout board PCSS, reset board
PCSS, release board PCSS command sequence.
2. Test the port again via the test port PCSS02 l command.
3. If the test fails again, replace the circuit pack.
PASS The Maintenance/Test Digital Port digital trunk testing capability is
operating correctly.
Table 10-299. TEST #161 Loop Around Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page