DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-68ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon Analog Line)
10
1004 ABORT System resources required to run this test are not available. The port may
be busy with a valid call. Use the display port PCSSpp command to
determine the station extension. Use the status station command to
determine the service state of the port. If the service state indicates that
the port is in use, then the port is unavailable for certain tests. (Refer to the
"Status Commands" section in Chapter 8, "Maintenance Commands and
Trouble-Clearing Aids", for a full description of all possible states.) You
must wait until the port is idle before retesting.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort and the port is not in use, escalate the
problem.
1005 ABORT The test was aborted due to a configuration problem. This code will result
under either of the following conditions:
1. This test may not be applicable, or it may be disruptive to terminal
equipment other than a voice terminal (for example, the modem pool
member or music on hold).
2. The circuit pack is one of the following:
TN742 vintages 13,14 and 15
TN769 vintages 3,4 and 5
1018 ABORT Test disabled via administration. The default for the 'Test' field on the
'Station' form is 'y'; thus, you may want to determine why this field has
been set to 'n' on this station (this may be due to the ringing application
test 48, which can be customer or terminal disturbing).
1. To enable the test for a particular station, enter change station
extension and set the ‘Test?’ field on the ‘Station Form’ to ‘y.’
1020 ABORT The test did not run due to a previously existing error on the specific port
or a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit
pack and attempt to diagnose the previously existing error.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT System resources required to run this test are not available. Either a
system allocation to get information about the port or to put the port into a
service state failed or the attempt to put the port in connection with a tone
source failed (this could be a tone-clock problem). The tone-clock and
tone detectors could be having a communication problem, for example,
the companding modes could be out of synchronization.
1. Retry the command at 1-minute intervals a maximum of 5 times.