DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1364TIE-DS1 (DS1 Tie Trunk)
10
FAIL The far-end trunk did not respond to the seizure of the near-end trunk
within the allowable time period. This test could have associated in-line
errors in the error log.
1. 1) Enter the list configuration board UUCSS command. If the circuit
pack is a TN767B vintage 8 or 9, a failure of test 136 causes a
subsequent failure of test 7 due to a firmware bug. Eventually, the
board and all of its ports will be taken out of service and extraneous
on-board alarms will be generated. Replace the circuit pack with a
TN767C V3 or later.
2. Verify that the ’Trunk Type’ field on the ’Trunk Administration’ screen
matches the trunk type administered on far-end switch.
3. Look for DS1-BD or UDS1-BD errors in the hardware error log. If
present, refer to the DS1-BD (DS1 trunk circuit pack) Maintenance
documentation or to the UDS1-BD (UDS1 trunk circuit pack)
Maintenance documentation.
4. Retry the test at 1 minute intervals for a maximum of 5 times.
5. If the test continues to fail, escalate the problem.
2000 FAIL Response to the seizure message was not received within the allowable
time period.
1. Enter the list configuration board UUCSS command. If the circuit
pack is a TN767B vintage 8 or 9, a failure of test 136 causes a
subsequent failure of test 7 due to a firmware bug. Eventually, the
board and all of its ports will be taken out of service and extraneous
on-board alarms will be generated. Replace the circuit pack with a
TN767C V3 or later.
2. Verify that the ’Trunk Type’ field on the ’Trunk Administration’ screen
matches the trunk type administered on far-end switch.
3. Look for DS1-BD or UDS1-BD errors in the hardware error log. If
present, refer to the DS1-BD (DS1 trunk circuit pack) Maintenance
documentation or to the UDS1-BD (UDS1 trunk circuit pack)
Maintenance documentation.
4. Retry the test at 1 minute intervals for a maximum of 5 times.
5. If the test continues to fail, escalate the problem.
PASS The trunk can be seized for an outgoing call.
Table 10-474. TEST #136 DS1 Tie Trunk Seizure Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page