DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-905OPS-LINE (DS1 OPS Line)
10
Table 10-306. TEST #312 DS1OPS Switchhook Inquiry Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal System Error.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
1004 ABORT The port has been seized by a user for a valid call. Use the status station
command to determine when the port is available for testing.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, and the port is not in use, escalate the
problem.
1005 ABORT Test failed due to incompatible configuration administered in station
administration.
1. Verify the station administration is the station assigned to Port 24 of the
DS1 Interface circuit pack while common channel signaling is specified.
1006 ABORT The test was aborted because the station is out of service. This condition may
be accompanied by an error type 18 entry in the error log. You may want to
determine why the station was taken out of service. (When stations are taken
out of service by maintenance software, the problems that led up to that must
be cleared.)
1. Use the status station command to check the state of the port. If the port
is indeed out of service, enter the release station command to bring the
station back into service.
2. Retry the command at 1-minute intervals a maximum of 5 times.
3. If the test continues to abort, and the station is in the in-service/idle state,
escalate the problem.
1020 ABORT The DS1 Interface circuit pack is out-of-service.
1. Look for DS1-BD errors in Hardware Error Log. If present, refer to the
DS1-BD (DS1 Interface Circuit Pack) Maintenance documentation.
2. Retry the command.
3. If the test continues to abort, escalate the problem.
Continued on next page