DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-16busyout sp-link
8
Output
Field descriptions
busyout sp-link
This command places the system printer link into a maintenance busy state. No
periodic or scheduled maintenance is performed on the busied out system
printer link until it is released. Warning alarms (error type 18) are generated on
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
busyout
pri-endpoint
extension
PRI endpoint
extension number
Examples:
busyout pri-endpoint
25012
busyout pri-endpoint
77868
init
inads
craft
nms
none If active calls resides
on specified PRI
endpoints, the
busyout command
drops the call.
Once the PRI endpoint
is maintenance-busy,
call attempts from
far-end PRI terminal
adapters are denied
with a cause value 17.
Port
Port address (cabinet-carrier-slot-circuit)
Maintenance Name
Type of busied out maintenance object: PE-BCHL
Alt. Name
Extension number of PRI endpoint
Result
Test result: Pass, Fail, Abort
Error Code
Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
busyout pri-endpoint 22501 SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
01B2001 PE-BCHL 22501 PASS
01B2002 PE-BCHL 22501 PASS
01B2003 PE-BCHL 22501 PASS
01B2004 PE-BCHL 22501 PASS
01B2005 PE-BCHL 22501 PASS
01B2006 PE-BCHL 22501 PASS
Command Successfully Completed