DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1421TONE-PT (Tone Generator)
10
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, follow normal escalation procedures.
FAIL The Tone Generator could be defective. In a Port Network with more than
one Tone-Clock circuit pack, the system will attempt to move the tone
generation function to the alternate one.
1. Test the Tone-Clock circuit pack again via the test tone-clock PC
command
2. If the test fails again, look at the Hardware Error Log for Tone Detector
circuit pack errors.
3. If there are Tone Detector circuit pack errors, refer to Tone Detector
Maintenance documentation (DTMR-PT, GPTD-PT, CLAS-PT, ETR-PT)
to resolve these errors first.
4. If there are no Tone Detector circuit pack errors, then the Tone-Clock
circuit pack should be replaced. See ‘‘
How to Replace a Tone-Clock
Circuit Pack’’ in the TONE-BD section.
PASS The tone generation facility is able to put tones out.
Table 10-486. TEST #90 Tone Generator Crosstalk Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page