DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1417TONE-PT (Tone Generator)
10
1002 ABORT The system could not allocate time slots for the test connection. This can
happen when the system is heavily loaded. If the system is not heavily
loaded, then test the TDM Bus via the test tdm port-network PN#
command. Refer to TDM-BUS section for details.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, follow normal escalation procedures.
1003 ABORT The system could not allocate a tone receiver for the test connection. This
can happen when the system is heavily loaded or there is not a Tone
Detector circuit pack in the port network where this test is being executed.
1. Make sure there is a Tone Detector circuit pack in the same port
network.
2. If a Tone Detector circuit pack is missing, install one in the same port
network.
3. Allow approximately 1 minute for Tone Detector maintenance to run on
the newly inserted Tone Detector circuit pack.
4. Retry the command at 1-minute intervals a maximum of 5 times.
5. If the test continues to abort, follow normal escalation procedures.
1022 ABORT [G3r V2] Tone detection for the system is administered as wide broadband
(tone detection mode 5), and the Tone Detector used for this test was not a
TN420C or TN2182 (the only circuit packs with this capability). GPTD ports
on other types of Tone Detector circuit packs are taken out of service since
they cannot provide the administered function.
1. Change the tone-detection mode administered on the
system-parameters country-options form (see
DEFINITY
Communications System Generic 3 V2 Implementation,
555-230-653,
Or
2. Remove all non-TN420C and non-TN2182 circuit packs from the
system.
2000 ABORT Response to the test request was not received within the allowable time
period. System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, follow normal escalation procedures.
2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, follow normal escalation procedures.
1 (a) FAIL DTMF generation failed for the active tone generator.
Table 10-484. TEST #40 Tone Generator Transmission Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page