Table 10-344. TEST #586 Packet Control Reset Test
Error
Code
Test
Result Description/ Recommendation
1029
2011
2012
2013
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT Refer to STBY-SPE Maintenance documentation for a description of these
error codes.
1015 ABORT The Packet Control circuit pack is not busied out.
1. Retry the command after running the busyout packet-control C
command.
1152 ABORT The Packet Control circuit pack hardware was successfully reset and the
circuit pack was successfully put back into service. However, a new image
of Packet Control circuit pack firmware was not able to be downloaded from
the tape, because the tape was unavailable. Nonetheless, the existing
firmware on the circuit pack is valid, and there is no need to repeat this test.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1-3 FAIL The reset test failed.
1. Retry the command.
2. If it fails again with the same error code, replace the Packet Control
circuit pack.
Continued on next page