DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-870M/T-ANL (Maintenance/Test Analog Port)
10
Table 10-292. TEST #13 Analog Port Digital Loop Around Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal System Error
1. Retry the command at 1 minute intervals a maximum of 3 times.
2. If the test continues to abort, escalate the problem.
1000 ABORT The port is in use on a valid ATMS Test Call.
1. Retry the command at 1 minute intervals a maximum of 3 times.
2. If the test continues to abort and the port is not in use on a valid
ATMS Test Call, escalate the problem. To determine whether the
port is in use by an ATMS Test Call enter status station ext where
ext is the assigned ATMS station number.
1001 ABORT System resources required to run this test are not available.
1. Retry the command at 1 minute intervals a maximum of 3 times.
2. If the test continues to abort, escalate the problem.
1002 ABORT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions, or it may have time slots out-of-service
due to TDM-BUS errors. Refer to TDM-BUS Maintenance to diagnose
any active TDM-BUS errors. A system is considered under heavy traffic
when the Call Processing Occupancy is greater than 50% or when the
System Management and the Call Processing Occupancies together
exceed 65%. To view the system occupancy measurements enter the
command status system health on the system technician terminal.
1. If the system has no TDM-BUS errors and is not handling heavy
traffic, repeat the test at 1 minute intervals a maximum of 3 times.
2. If the test continues to abort, escalate the problem.
1003 ABORT The system could not allocate a tone receiver for the test. The system
may be oversized for the number of tone detectors present, or some
tone detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer to
TTR-LEV Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to
TONE-PT Maintenance documentation.
3. If neither condition exists, retry the command at 1 minute intervals a
maximum of 3 times.
4. If the test continues to abort, escalate the problem.
Continued on next page