Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1181STBY-SPE (Standby SPE)
10
2025
(cont’d.)
ABORT If none of the three red LEDs is on AND if this is the fourth attempt to
clear the problem (that is, the Standby SPE Processor, Standby SPE
Memory, and carrier A Duplication Interface circuit packs have already
been replaced), proceed with Step 10.
If none of the three red LEDs is on AND if this is the fifth attempt to clear
the problem (the Standby SPE Processor, Standby SPE Memory, and
carrier A Duplication Interface circuit packs have been replaced and
the test has been repeated once), escalate the problem.
10. Issue the refresh spe-standby command to put the Standby SPE into
Standby Mode. This command may have to be issued multiple times. If the
refresh spe-standby command successfully completes five times without
the Standby SPE becoming labeled "standby" on the status system form,
wait 20 minutes. This does not include cases where the command
completes with the terminal message line errors "Refresh not successful;
use ‘display errors’ to check for STBY-SPE errors" or "Cannot interrupt
Standby SPE while entering maintenance mode; please try later." Issue the
refresh spe-standby command once more. If the Standby SPE is not
labeled "standby" on the status system form after this attempt, use the
busyout spe-standby and release spe-standby command to put the
standby into standby mode.
11. Repeat the command.
12. Issue the test spe-standby long command.
Table 10-410. Test Result Error Codes Associated with the Standby SPEContinued
Error
Code
Test
Result Description/ Recommendation
Continued on next page