Maintenance Object Repair Procedures
Page 10-1466UDS1-BD (UDS1 Interface Circuit Pack)
10
2000 ABORT Response to the test was not received within the allowable time period.
This may be due to hyperactivity. Error type 1538 in the error log indicates
hyperactivity. The hyperactive circuit pack is out of service and one or
more of the following symptoms may be exhibited.
1. The UDS1-BD tests (such as test 138 and test 139) are aborting with
error code 2000.
2. The tests run on the ports of this circuit pack are returning a no board
result.
3. A busyout or a release command has no affect on the test results.
4. A list config command shows that the circuit pack and the ports are
properly installed.
When hyperactivity occurs, the circuit pack is isolated from the system,
and all of the trunks for this circuit pack are placed into the out of service
state. The system will try to restore the circuit pack within 15 minutes. When
no faults are detected for 15 minutes, the UDS1 interface circuit pack is
restored to normal operation. All of the trunks for the UDS1 interface circuit
pack are then returned to the in service state. Hyperactivity is often caused
by the associated facility. In such a case, faults (such as slips, misframes,
or blue alarms) would be entered in the error log. In addition, many
hardware errors would be logged against the associated trunk circuits. If
the facility is OK and the error occurs again after 15 minutes, replace the
circuit pack.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
FAIL The remote DS1 endpoint is out-of-service.
1
1794
FAIL The UDS1 Interface circuit pack detects a Line Loopback Alarm (LLB).
If the UDS1 interface circuit pack connects to a T1 facility, call the vendor
of the T1 carrier to diagnose the remote DS1 endpoint.
If the UDS1 interface circuit pack connects directly to a switch, call the
system technician of the remote switch to diagnose the DS1 endpoint.
If the UDS1 interface circuit pack connects directly to a line-side
terminating device (for example, a PRI terminal adapter), call the vendor of
the terminating device to diagnose the equipment.