DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-692HYB-LINE (Hybrid Line)
10
Hybrid Line Lamp Updates Test (#60)
For this test, the software lights the lamps on the terminal based on the status
record contained in the processor. The lamp updates run only if the station is
in-service.
1,2,3 FAIL No response was received within the allowable time period on one of the
transmissions to the terminal. This indicates that something is wrong with
the data link to the voice terminal. This could be a sleeping set problem or
it may be due to wiring or an unplugged or defective set.
1. Check for errors in the error log, for example, error 1537.
2. Remotely issue the busyout and release busy commands, and run
the short test sequence on the port to check for other errors
associated with the port or terminal.
3. Check the wiring to the set if it appears that the terminal is not
responding to any tests; otherwise, replace the terminal and rerun the
test.
4. If the test still fails, replace the circuit pack and reconnect the original
terminal.
PASS Hybrid Line Remote Digital Loop Around Test passed. The hybrid circuit
pack is sending and receiving proper messages to and from the voice
terminal.
1. If problems still exist, investigate using other circuit pack tests and by
examining the station, wiring, and connections.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the
busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the
linkage between the internal ID and the port. If this is not the case,
dispatch to check to ensure that there is a valid board inserted.
Table 10-230. TEST #59 Hybrid Line Remote Digital Loop Around Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page