Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Architecture
Page 1-2Alarm and Error Reporting
1
Alarm and Error Reporting
During normal operations, software or firmware may detect error conditions
relevant to specific MOs. The system attempts to fix or circumvent these
problems automatically. However, if a hardware component incurs too many
errors, an alarm is raised. Errors are detected in two ways:
For “in-line” errors, firmware on the component detects the
occurrence of an error during ongoing operations.
For other types of errors, a “periodic test” or a “scheduled test”
started by the software detects the error. The technician can run
these tests on demand by using the maintenance commands
described in Chapter 8, ‘‘
busyout journal-printer’’, and Chapter 10,
‘‘Maintenance Object Repair Procedures’’.
Software puts the error in the error log, and increments the error counter for that
error. When an error counter is “active,” (greater than zero), there is a
maintenance record for the MO.
Alarms are classified as MAJOR, MINOR, or WARNING, depending on the effect
on system operation. They are also classified as ON-BOARD or OFF-BOARD.
MAJOR alarms identify failures that cause a critical degradation of
service. These alarms require immediate attention.
MINOR alarms identify failures that cause some service degradation but
that do not render a crucial portion of the system inoperable. MINOR
alarms require attention. However, typically a MINOR alarm affects only a
few trunks or stations or a single feature.
WARNING alarms identify failures that cause no significant degradation of
service or equipment failures external to the switch. These failures are not
reported to INADS or to the attendant console.
ON-BOARD problems originate in the circuitry on the alarmed circuit
pack.
OFF-BOARD problems originate in a process or component that is
external to the circuit pack.
Alarms are discussed further in Chapter 10, ‘‘
Maintenance Object Repair
Procedures’’.
Maintenance Testing
Most troubles are reduced to the circuit pack level and can be identified by LEDs
on the circuit packs and software reports generated by the system. The
maintenance tests in the system are divided into three groups:
Periodic