DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-94enable synchronization-switch
8
enable synchronization-switch
This command re-enables automatic clock switching or returns the maintenance
subsystem back to the normal state. The synchronization subsystem consists of
the TDM bus clock, DS1 trunk board, and SPE-resident maintenance and
administration software and provides error free digital communication between
the switch and other PBXs, COs, or customer-premise equipment (CPE).
enable test-number
This command enables a previously disabled test number. At the next request by
maintenance or the technician, this test number runs.
format card-mem
This command erases and formats the active processor Flash Read-Only
Memory card before writing translation, announcements, coredump, and
firmware data.
Output
The server shows the active SPE and returns Command completed
successfully if completed.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
enable synchronization-switch init
inads
craft
none none
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
enable
test-number
number
The specific test number
to re-enable
Example:
enable test-number 102
init
inads
craft
none The display
disabled-tests
command gives
a list of all
disabled tests.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
format
card-mem
translation
announcements
coredump
firmware
Erases and formats the memory
card for:
translations only
translations and announcements
translations, announcement, and
coredump
translations, announcements
coredump, and firmware
init
inads
craft
cust
browse
system
none none