DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-322CO-TRK (CO Trunk)
10
1006 ABORT The port has been placed out of service, perhaps by craft busyout. Use the
display port PCSSpp command to determine the trunk group/member
number of the port. Use the status trunk command to determine the
service state of the port. If the service state indicates that the port is in use,
then the port is unavailable for certain tests. You must wait until the port is
idle before retesting.
1. If the port status is idle, retry the command at 1 minute intervals for a
maximum of 5 times.
2. If the test continues to abort, escalate the problem.
2100 ABORT System resources required to run this test were not available.
1. If the port status is idle, retry the command at 1 minute intervals for a
maximum of 5 times.
2. If the test continues to abort, escalate the problem.
FAIL Internal system error.
1. Retry the command at one-minute intervals a maximum of five times.
2. If test continues to fail, escalate the problem.
PASS This test passed. Translation information was successfully updated on the
circuit pack. User-reported troubles on this port should be investigated by
using other port tests and by examining trunk or external wiring. If the trunk
is busied out, the test does not run, but returns PASS. To verify that the
trunk is in-service:
1. Enter status-command to verify that the trunk is in-service. If the trunk
is in-service, no further action is necessary. If the trunk is
out-of-service, continue to Step 2.
2. Enter release-trunk command to put trunk back into in-service.
3. Retry the test command.
0NO
BOARD
The test could not relate the internal ID to the port (no board).
1. Check to ensure that the board translations are correct. Translate the
board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish the linkage
between the internal ID and the port.
Table 10-105. TEST #36 Port Audit Update Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page