DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-28change system-parameters maintenance
8
Field descriptions
change system-parameters
maintenance
This command specifies and displays scheduled maintenance operations and
maintenance support functions. It also activates and deactivates INADS alarm
origination during repairs. To deactivate alarm origination:
1. Make a note of the current entries in the Alarm Origination and CPE Alarm
fields so you can restore them later.
2. Change the Alarm Origination to OSS Numbers field to “neither.”
3. Change the CPE Alarm Activation Level field to “none.”
4. If daily scheduled maintenance must remain idle during a maintenance
procedure, set the Start Time field to a time after the session ends. If
daily Scheduled Maintenance is running and needs to be deactivated, set
the Stop Time field to one minute after the current time.
Stratum: Current synchronization stratum (3, 4)
Primary: First choice system synchronization source (blank entry = no
synchronization); field valid only if stratum 4 synchronization is
specified.
Secondary: Second choice system synchronization source (blank = no
synchronization); valid if stratum 4 synchronization selected
Location: Circuit pack location of all administered DS1 circuit packs (port
network, carrier and board slot)
Name: User-defined name for the DS1 circuit pack (blank = no user-defined
name assigned)
Slip: If DS1 circuit pack has slip alarm, y; if not, n.
Port
Network:
Display-only field specifying the port network that supplies
synchronization through the tone clock circuit pack (valid for stratum 3
synchronization)
change synchronization Page 1 of 1
SYNCHRONIZATION PLAN
SYNCHRONIZATION SOURCE (DS1 circuit pack location)
Stratum: 3
Port Network: 1