Maintenance Commands and Trouble-Clearing Aids
Page 8-214status access-endpoint
8
status access-endpoint
This command displays diagnoses internal software and helps to locate facilities
with which Access Endpoints communicate.
7y y y n
8n n n y
9y n n y
an y n y
by y n y
cn n y y
dy n y y
en y y y
fy y y y
spe-standby
The default option for a High or Critical Reliability System. If a restart
occurs on active SPEs and the corresponding vector bit is set, a core
dump occurs on the standby SPE (after the standby SPE has performed
a memory refresh).
spe-active
Option for a High or Critical Reliability System; default for simplex SPE
systems. If a restart occurs on active SPEs and the corresponding
vector bit is set, core dumps occur on the active SPE. This option
disrupts service.
spe-maint
Available for High or Critical Reliability Systems. If restarts occur on
active SPEs and the corresponding vector bit is set, core dumps occur
on standby SPEs without the standby SPE a memory refresh.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
status
access-endpoint
extension
print
extension number of the access
endpoint
prints reports to SAT printers.
Examples:
status access-endpoint 25012
status access-endpoint 77868
status access-endpoint 66078
print
init
inads
craft
cust
nms
browse
none none
Vector-Condition Mapping
value WARM COLDII COLDI REBOOT