Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1524VC-BD
10
Notes:
a. The circuit pack stopped functioning or it was removed from the system.
This alarm is logged approximately 11 minutes after the circuit pack is
removed and/or the SAKI Sanity Test (#53) fails.
To resolve this error, insert a circuit pack in the same slot as the error
indicates, if the circuit pack is not already in the system. Or, if the circuit
pack is in the system and the red LED is on, then follow instructions for
Red alarms.
!
CAUTION:
If the TN788 Voice Conditioner Circuit Pack (VC-BD) is not Vintage 2
or later, it must be replaced.
b. This circuit pack is busied out by the busyout board PCSS command.
c. Transient communication problems exist between the switch and this
circuit pack. Execute the test board PCSS command and refer to the
repair procedures for the Control Channel Loop Around Test (#52).
d. The circuit pack detected an on-board hardware failure. The reported aux
data values correspond to the following detected errors:
1. Run the short test sequence first. If all tests pass, run the long test sequence. Refer to the
appropriate test description and follow the recommended procedures.
1025 (f) 4363 NPE Audit Test (#50)
1281 (g) Any SAKI Sanity Test (#53) MAJ ON
1293 to
1294 (h)
46088
to
46096
SAKI Sanity Test (#53) MIN ON See note (g)
1538 (i) 46082 MIN ON
Error Description
4352 External RAM error
4353 Internal RAM error
4355 ROM Checksum error
4357 Instruction set error
Table 10-512. VC-BD Error Log Entries — Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page