DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-706ISDN-LNK (ISDN-PRI Signaling Link Port)
10
NPE Crosstalk Test (#6)
The NPE Crosstalk Test verifies that this port’s NPE channel talks on the selected
time slot and never crosses over to time slots reserved for other connections. If
the NPE is not working correctly, one-way and noisy connections may be
observed. This test is usually only part of a port’s Long Test Sequence and takes
about 20 to 30 seconds to complete. This test runs only if the Processor Interface
link corresponding to this ISDN-LNK MO is busied out by system technician. The
Processor Interface link number can be determined from the
Communication-Interface Links form.
Table 10-236. TEST #6 NPE Crosstalk Test
Error
Code
Test
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources for this test are not available. The ISDN-PRI link may be
up and servicing calls. First obtain the ISDN-PRI link number (lnk-no) from
the Communication-Interface Links form by issuing the display
communication-interfaces links command. Then, determine the status of
the ISDN-PRI link via the status link lnk-no command. If the link is
in-service, this test aborts. Therefore, to run this test, the link must be busied
out. No new ISDN-PRI calls can be made while the link is in the busied-out
state.
1. If the test must be run, busyout the link.
2. Retry the command.
1001 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors. Refer to TDM-BUS (TDM Bus) Maintenance to diagnose
any active TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat the test at 1-minute intervals a maximum of 5 times.
Continued on next page