DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-468DIOD-TRK (DIOD Trunk) [G1.2SE]
10
1002 ABORT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due
to TDM-BUS errors. Refer to TDM-BUS (TDM Bus) Maintenance
documentation to diagnose any active TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
1004 ABORT The port has been seized by a user for a valid call. Use the status trunk
command to determine when the port is available for testing.
1. Retry the command at one minute intervals a maximum of five times.
2. If the test continues to abort and the port is not in use, escalate the
problem.
1018 ABORT Test has been disabled via administration.
1. Verify that the "Maintenance Tests?" field on the Trunk Group Form is
set to "n." To enable the test, issue the change trunk-group x
command where "x" equals the number of the trunk group to be tested.
Then change the entry in the "Maintenance Tests?" field on the form to
"y."
1005 ABORT Trunk has been administered as incoming-only; or DID trunk group type;
dial tone can only be obtained on outgoing trunks. This is a normal
condition.
2000 ABORT Response to the test was not received within the allowable time period.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
FAIL Trunk was seized, but dial tone could not be detected.
1. Check for errors on TONE-BD or TONE-PT. Clear any errors found and
repeat test.
2. If error has still not cleared, refer problem to CO.
2002 FAIL Seizure portion of test failed due to hardware problem. Fault is usually
caused by a disconnected trunk.
1. Check trunk wiring to ensure good connection; repeat test if wiring
correction made.
2. Locate another identical CO trunk and swap its wiring with one under
test. Repeat test on both trunks and determine if problem follows trunk
or remains at original port. If problem follows trunk, refer problem to
CO. If problem remains at port, replace circuit pack and repeat test.
3. If replacing circuit pack does not clear failure, escalate the problem.
Table 10-155. TEST #0 Dial Tone Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page