Maintenance Object Repair Procedures
Page 10-1112S-SYN-PT (Speech Synthesis Port)
10
Table 10-396. TEST #165 Speech Synthesis DSP Tone Test
Error
Code
Test
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call and therefore unavailable for certain tests. You must wait
until the port is idle (yellow LED if off) before retesting.
1. If the port is idle retry the command at one-minute intervals a maximum of
five times.
2. If the test continues to abort, escalate the problem.
1001
1002
1003
ABORT System resources required to run this test are not available.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
1021 ABORT The 440-Hz tone was not detected by the Tone Detector circuit and inter-digit
time-out has occurred on the Tone Detector circuit.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, verify all Tone Detector circuit packs in the
system are functioning correctly by checking the Error Log and using the
test board PCSS long command. Replace any faulty Tone Detector circuit
packs and repeat the test.
3. If the test continues to abort, replace the Speech Synthesis circuit pack.
2000 ABORT Response to the test request was not received within the allowable time period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
Any FAIL The 440-Hz tone was not detected by the Tone Detector circuits.
1. If the test fails again, verify all Tone Detector circuit packs in the system are
functioning correctly by checking the Error Log and using the test board
PCSS long command. Replace any faulty Tone Detector circuit packs and
repeat the test.
2. If the test fails again, replace the Speech Synthesis circuit pack.
PASS The 440-Hz tone has been detected correctly. User-reported troubles should
be investigated using other tests and verifying other ports on this circuit pack
are working correctly.
Continued on next page