DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-358test journal-printer
8
Feature Interactions
The maintenance of a particular component on a link sometimes interferes with
the maintenance of the link itself. Maintenance can put a link component in a
busy state causing link set-up to fail. Frequent attempts at re-setup of a link may
delay the recovery of a faulty component due to the maintenance test of a
component only taking place when the component is idle. Therefore, the
1. If no alarms are registered against the maintenance object then the test sequence is run only once. The
long clear
option forces a clear of all alarms if no errors are encountered during testing. The
short clear
option only clears alarms
pertinent to tests in the short sequence.
2. Refer to the Report Scheduler and System Printer feature specification for more details.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
test
journal-printer
pms-log
wakeup-log
short
long
repeat
number
clear
schedule
Tests the link to the pms logging
printer (maintenance name =
PMS-PRNT)
Tests the link to the wakeup logging
printer (maintenance name =
JNL-PRNT)
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive series of both
destructive and nondestructive
diagnostic tests.
Number of times each test in the
sequence is repeated (1-100)
This option causes the test sequence
(short or long) to repeat until the alarm
(if any) is cleared or a single test in the
sequence fails.
1
Command is validated and then a
scheduling form displays to schedule
execution of the command. The
command is then placed in the
command queue and is executed at
the specified time. The information
displayed by the command is sent to
the system printer instead of the
screen.
2
Examples:
test journal-printer pms-log l
test journal-printer pms-log l
schedule
test journal-printer wakeup-log r 2
test journal-printer wakeup-log r 2
schedule
test journ pm r 3
test journ pm r 3 schedule
init
inads
craft
Test
sequence
= short;
repeat = 1
See below