Maintenance Object Repair Procedures
Page 10-682HYB-LINE (Hybrid Line)
10
Table 10-227. TEST #56 Hybrid Electronic Power Feed Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal System Error.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not available. The port may
be busy with a valid call. Use the display port PCSSpp command to
determine the station extension number of the port. Use the status station
command to determine the service state of the port. If the service state
indicates that the port is in use, then the port is unavailable for certain
tests. (Refer to the "Status Commands" section in Chapter 10,
"Maintenance Commands and Trouble-Clearing Aids" for a full description
of all possible states.) You must wait until the port is idle before retesting.
Attendants are always in use (off-hook) if the handset is plugged in and the
port is not busied out.
1. If the port status is idle, then retry the command at one-minute
intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
FAIL Internal System Error.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
PASS EPF test passed. The message to turn on the power to the station was
successfully sent to the port.
1. Although this test never returns a FAIL result, after running this test, the
Error Log should be checked for any entries with Error Type 257 to
examine the real results of this test.
2. If Error Type 257 does not appear in the Error Log within 10 seconds
after completion of this test, it is safe to assume that the test sensed no
problems with the power to the station. To verify that the station is
powered up correctly, run a self-test on the station, if available, and
check that all the feature buttons are operating.
3. If Error Type 257 appears in the Error Log, this indicates some
problem with the power to the station. The system technician should
check for a short in the wiring, a damaged jack, a defective voice
terminal, or an incorrect type of terminal.