DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1491UDS1-BD (UDS1 Interface Circuit Pack)
10
Translation Update Test (#146)
The Translation Update Test sends the circuit-pack-level information specified by
System Administration to the UDS1 Interface circuit pack. Translation includes
the following data administered for a UDS1 Interface circuit pack (see output of
display ds1 PCSS command): DS1 Link Length between two DS1 endpoints,
Synchronization Source Control, All Zero Suppression, Framing Mode, Signaling
Mode, Time Slot Number of 697-Hz Tone, Time Slot Number of 700-Hz Tone, etc.
In G3V3, if a TN464F or later UDS1 circuit pack is combined with an AT&T 120A1
CSU Module to form and Integrated CSU Module, this test will also send the
administration for this Integrated CSU to the circuit pack to assure the board’s
translations are correct. The administration of the CSU Module is done using the
DS1 circuit pack administration form. Translation for the CSU Module includes
the following data: Transmit LBO, Receive ALBO, Supply CPE Loopback Jack
Power?, etc.
Table 10-502. TEST #146 Translation Update Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal System Error
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
FAIL Internal system software error.
1. Enter the display ds1 PCSS command to verify the UDS1 Interface
circuit pack translation.
2. If the test continues to fail, escalate the problem.
PASS Translation data has been downloaded to the UDS1 Interface circuit pack
successfully.
Continued on next page