DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-316test access-endpoint
8
test access-endpoint
This command performs hardware diagnostic tests on all port circuits that are
associated with the specified access endpoint extension.
1. If no alarms are registered against the maintenance object then the test sequence is run only once. The
long clear
option forces a clear of all alarms if no errors are encountered during testing. The
short clear
option only clears
alarms pertinent to tests in the short sequence.
2. Refer to the Report Scheduler and System Printer feature specification for more details.
Action/
Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
test
access-
endpoint
extension
short
long
repeat
number
clear
schedule
Access endpoint extension (# of digits
determined by dial-plan)
Option for a brief series of nondestructive
diagnostic tests.
Option for a longer, more comprehensive
test series (includes a destructive test)
How many times each test in the sequence
is repeated (1-100)
This option causes the test sequence (short
or long) to repeat until the alarm (if any) is
cleared or a single test in the sequence
fails.
1
Command is validated and then a
scheduling form displays to schedule
execution of the command. The command is
then placed in the command queue and is
executed at the specified time. The
information displayed by the command is
sent to the system printer instead of the
screen.
2
Examples:
test access-endpoint 25012
test access-endpoint 45002 sh
test access-endpoint 45892 l
test access-endpoint 24389 sh r 4
test access-endpoint 34899 l r 6
test access-endpoint 34912 l r 5 schedule
test access-endpoint 93483 r 2
test access-endpoint 10022 c
test access-endpoint 92349 schedule
init
inads
craft
nms
Test
sequence
= short;
repeat =
1
none