DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1562XXX-BD (Common Port Circuit Pack)
10
SAKI Sanity Test (#53)
This test is destructive.
This test resets the circuit pack.
This test is executed as part of the long test sequence only for the Tone-Clock
circuit pack and DS1 interface circuit packs. All other common circuit packs can
be reset via the reset board PCSS command. The reset command executes this
test.
FAIL The test failed because the circuit pack failed to return the circuit pack
code or vintage.
1. Retry the command for a maximum of 5 times.
2. If the test still fails, issue the busyout board, reset board, and
release busy board commands, and then retest.
3. If the problem continues, replace the circuit pack.
4. Run the test again.
5. If the test continues to fail, escalate the problem.
PASS Communication with this circuit pack is successful.
EXTRA BD This result should only appear for the TN771B or TN771C
Maintenance/Test circuit pack. More than one circuit pack has been
installed in this port network. Remove this circuit pack.
any NO BOARD This is normal if the test is being done when (a) the circuit pack is not
physically in the system or (b) the system is booting up. Otherwise, there
is some inconsistency between the physical configuration and the data
kept in the system.
1. Verify that the circuit pack is physically in the system.
2. Verify that the system is not in a stage of booting up.
3. ) Retry the command at one-minute intervals for a maximum of five
times.
4. If the test continues to return NO BOARD, escalate the problem.
Table 10-528. TEST #52 Control Channel Loop Around Test — Continued
Error
Code Test Result Description/ Recommendation
Continued on next page