Page 10-1028POWER (Battery & Battery Charger) for AC-Powered Systems
10
4FAIL
(cont’d.)
3. If the batteries were replaced, it can take up to 24 hours for the new
batteries to be charged (new batteries are shipped uncharged). If Test #5
is run again before the batteries are completely charged, the test fails. If
the charger was replaced, some time must be allowed for the new charger
to recharge the batteries. Therefore, in either case, wait at least 24 hours
and rerun the test. If the test still fails, the PR-MAINT (Maintenance/Tape
Processor) in a multicarrier cabinet PPN system without High or Critical
Reliability, the DUPINT (Duplication) Interface circuit pack in a PPN for a
system with High or Critical Reliability, or the EPN MAINT (Maintenance)
circuit pack in an EPN could be reporting this condition incorrectly. There
are failures that can occur on the Maintenance/Tape Processor,
Duplication Interface, and EPN Maintenance circuit pack that ARE NOT be
detected by the respective maintenance, but that cause many, if not all,
environment tests to fail. If many environment tests are failing, the suspect
circuit pack, depending on the system configuration, should be replaced
and the test rerun. Resolve all alarms on these MOs, and rerun the test. If
the test still fails, escalate the problem.
6 FAIL This indicates that Error Codes 2 and 4 have occurred. Refer to these
descriptions. Also, refer to the description for Error Code 14 for this test.
Table 10-350. TEST #5 Battery & Battery Charger Query Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page