Page 10-1039PR-MAINT (Maintenance Processor [TN790 RISC Systems])
10
MTP Outpulse Relay Test (#102)
This test is a nondestructive test.When the internal modem is administered, the
test validates the correct operation of the remote access CO trunk used by
INADS. The MTP first goes off-hook, then on-hook on this trunk. If the loop current
is detected, the test passes. If the external modem is administered the MTP
sends an AT command sequence that will cause the external modem to go
OFF-HOOK and wait for dial-tone. If the modem detects dial-tone, the test
passes. This test is not allowed if the remote access line is in use.
PASS The Maintenance Processor was reset, and it passed initialization correctly.
The other MTP tests should be examined to verify that the MTP is functioning
correctly.
1. Enter test processor a/b and verify that the MTP is functioning correctly.
Table 10-355. TEST #102 MTP Outpulse Relay Test
Error
Code Test Result Description/ Recommendation
100 ABORT The test did not complete within the allowable time period.
1. Retry the command.
1018 ABORT The test has been disabled via administration.
1. To enable the test, issue the change system-parameters
maintenance command, and set the test remote access port field to
‘‘y.’’ (If you have an INADS line, set the field to ‘‘y.’’
2. Rerun the test.
1030 ABORT This test is not run on the Standby SPE.
1131 ABORT INADS port is busy because the system is reporting alarms to INADS, or
because INADS is dialed into the system.
1. If INADS is communicating with the switch the INADS trunk is working.
There is no need to run this test.
2. Or if required. Wait about ten minutes (until the INADS session is
terminated) and then re-enter the command.