DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-31change system-parameters maintenance
8
Operations Support Parameters
Product
Identification
Identifies switch to an Operations Support System (OSS): 10-digit
number starting with 1.
First OSS
Telephone
Number
Switch reports alarms first to the First OSS telephone number (for
example, INADS or Trouble Tracker). The number must be obtained
from the National Customer Support Center (NCSC) or the TSC. (# and
* are not allowed in the telephone number.)
Abbrev Alarm
Report
Enables the Abbreviated Alarm Report feature for the first OSS. (yes)
Second OSS
Telephone
Number
The switch reports alarms secondly to the second OSS telephone
number. For example, INADS or DEFINITY SNMP. The number must be
obtained from the National Customer Support Center (NCSC) or the
TSC. (# and * are not allowed in the telephone number.)
Abbrev Alarm
Report
Enables the Abbreviated Alarm Report feature for the second OSS. (no)
Alarm
Origination to
OSS Numbers
Indicates one of four options for alarm origination (neither):
”both” = Major and Minor alarms result in an automatic call to both
administered OSS telephone numbers.
“first-only” = Major and Minor alarms result in an automatic call to the
first administered OSS number.
“neither” = alarm origination does not occur; reports are not sent to
either number.
“second no-backup” = Major and Minor alarms result in an automatic
call to the first administered OSS telephone number. If calling the first
OSS telephone number fails four times, the switch calls the second
administered OSS telephone number until calling the first OSS
telephone number is successful.
NOTE:
Before Release 5, the name of this field is Alarm Origination
Activated.
If Alarm Origination is deactivated, Cleared Alarm Notification and
Restart Notification deactivate, even though they may still be activate in
the administration.
Cleared Alarm
Notification
The switch originates calls to the OSS and sends an alarm resolution
message once all previously-reported Major and Minor alarms are
resolved. Activate Alarm Origination to enable Cleared Alarm
Notification. (no)
Restart
Notification
Enables the switch to originate calls to the OSS and report any system
restarts caused by switch problems. Activate Alarm Origination to
enable Restart Notification.