DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-339test duplication-interface
8
DUPINT is associated with the duplication interface circuit packs other
functions, including SPE-to-SPE communication, SAT connection, and
environmental maintenance leads.
1. If no alarms are registered against the maintenance object then the test sequence is run only once. The
long clear
option forces a clear of all alarms if no errors are encountered during testing. The
short clear
option only clears
alarms pertinent to tests in the short sequence.
2. Refer to the Report Scheduler and System Printer feature specification for more details.
Action/
Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
test
duplication-
interface
location
short
long
repeat
number
clear
schedule
SPE location of the duplication
interface circuit pack (1a, 1b, a, or
b)
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive test series
(includes a destructive test)
How many times each test in the
sequence is repeated (1-100)
This option causes the test
sequence (short or long) to repeat
until the alarm (if any) is cleared or
a single test in the sequence fails.
1
Command is validated and then a
scheduling form displays to
schedule execution of the
command. The command is then
placed in the command queue and
is executed at the specified time.
The information displayed by the
command is sent to the system
printer instead of the screen.
2
Examples:
test duplication-interface a
test duplication-interface b sh
test duplication-interface a l r 25
test duplication-interface 1b l r
25 schedule
test duplication-interface 1a l c
init
inads
craft
Text
sequence
= short;
repeat = 1
Duplication-
interface
failures may
prevent SPE
switching.