Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-230status bri-port
8
BRI 0-126 Established ext blank Normal state for non-MIM initializing,
fixed and automatic TEIBRI
endpoints.
BRI, ASAI 64-126 Established blank blank Transitory state for automatic TEIBRI
endpoints which support MIM
initialization.
1. Verify that SPID administration
on the switch and endpoint are
consistent. Verify the repair by
executing the status bri-port
PCSSpp command. Determine
that the L2 state of the signaling
link is L3-Established.
Otherwise, proceed to Step 2.
2. Try to replace the endpoint.
Verify the repair by executing
the status bri-port PCSSpp
command. Determine that the
L2 state of the signaling link is
L3-Established.
BRI 64-126 L3-Established ext blank Normal state for automatic TEIBRI
endpoints supporting MIM
initialization.
BRI, ASAI 64-126 L3-Established blank yes Technicians conduct SPID
facilitation tests on the port. Links
are not associated with BRI port
endpoints. See description of SPID
Facility Test Procedures in the
‘‘
BRI-SET, ASAI-ADJ, BRI-DAT’’
Maintenance documentation.
BRI 64-126 L3-Established ext yes Technicians conduct SPID
facilitation tests on the port. Links
are associated with port endpoints.
See description of SPID Facility Test
Procedures in the ‘‘
BRI-SET,
ASAI-ADJ, BRI-DAT’’ Maintenance
documentation.
Table 8-3. Status BRI-Port Command Interpretation — Continued
Endpoint
Types
TEI
Range Layer 2 State
Voice
Extension
Service
SPID Description / Recommendation
Continued on next page