Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-693HYB-LINE (Hybrid Line)
10
Table 10-231. TEST #60 Hybrid Line Lamp Updates Test
Error
Code
Test
Result Description/ Recommendation
1 ABORT A request for a remote station lamp update aborted even though all
internal resources were correctly allocated.
1. Look in the error log for error type 18 (port busied out) for this port. If
this error type is present, release the port via the release port
PCSSpp command or the release station extension command, and
then run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals for a maximum of 5 times.
4. If the test continues to abort, escalate the problem.
2 ABORT Internal System Error.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
3 ABORT The station is in a ready for service or an out of service state. This may be
due to wiring or an unplugged or defective set.
1. Make sure terminal is connected and the wiring is correct.
2. Retry the command at 1-minute intervals a maximum of 5 times.
3. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not available. The port may
be busy with a valid call. Use the display port PCSSpp command to
determine the station extension number of the port. Use the status station
command to determine the service state of the port. If the service state
indicates that the port is in use, then the port is unavailable for certain
tests. (Refer to the "Status Commands" section in Chapter 10,
"Maintenance Commands and Trouble-Clearing Aids" for a full description
of all possible states.) You must wait until the port is idle before retesting.
Attendants are always in use (off-hook) if the handset is plugged in and the
port is not busied out.
1. If the port status is idle, then retry the command at one-minute
intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
FAIL Internal System Error.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
PASS Hybrid Line Lamp Updates completed successfully.
1. If complaints still exist, investigate by using other circuit pack tests,
and by examining the station, wiring, and connections.
Continued on next page