DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-45ANL-16-L (16-Port Neon Analog Line)
10
Hardware Error Log Entries and Test to Clear
Values
Notes:
a. This is an in-line error and can only be resolved over time. This indicates
that no terminal equipment was present when ringing was attempted.
Execute the short test port PCSSpp command, and follow the procedure
for the results of Test #48.
40960indicates that too many simultaneous incoming ringing
attempts were made on this board. Only four ports on a board may
be ringing simultaneously. A fifth incoming call will cause an inline
error from the board.
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate test
description and follow the recommended procedures.
2. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the set options
command.
Table 10-19. 16-Port Neon Analog Line Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test port PCSSpp sh r 1
1 (a) 40960
40977
none
15 (b) Any Audits and Updates
Test (#36)
18 0 busyout station
<extension>
WRN ON release station <extension>
130 (c) None WRN ON test port PCSSpp sh
257 (d) 40973 none
513 (e) Station Present Test
(#48)
WRN OFF test port PCSSpp sh r 2
769 Battery Feed Test
(#35)
MIN/WRN
2
ON test port PCSSpp sh r 2
1025 Loop Around Test
(#161)
MIN/WRN
2
ON test port PCSSpp l r 2
1281 Conference Test (#7) MIN/WRN
2
ON test port PCSSpp l r 2
1537 NPE Crosstalk Test
(#6)
MIN/WRN
2
ON test port PCSSpp l r 2